DRF
|
|
|
Description
|
|
|
The
DRF is a compact, DIN-rail mounted controller for use with
proportional solenoid valves. The DRF can be set to operate in open
loop (current feedback) mode or closed loop (external feedback) mode.
In open loop mode the controller provides current to a valve coil in
proportion to an input signal. In closed loop mode the controller
uses external feedback to maintain a velocity or pressure proportional to an input signal. The loop closure utilizes industry
standard PID control algorithms. Bright LED indicators on the front
of the unit provide an overview of the operating status. Setup is
accomplished through a convenient hand held interface or a PC. Once
configured, the settings are stored in permanent memory within the
unit. The DRF enclosure features convenient DIN-rail mounting and
removable terminal blocks.
|

|
|
Features
|
|
|
- Easily configured using WhiteOak Terminal Windows based software or our Hand Held Interface
- Front panel indicators for Power, Output Current and System Faults
- USB port for setup and monitoring
- Standard 35mm DIN rail mounting
- Removable terminals to simplify wiring and maintenance
- Control input options include +/-10V and 4-20mA
- Adjustable current limited output with short circuit protection
- Selectable dither frequency up to 1000 Hz
- Reference voltage outputs for potentiometer/joystick controls
- Multiple modes for single and dual coil, open or closed loop applications
- Independently adjustable min and max settings for input and output
- Adjustable ramp up and ramp down rates
- Microprocessor controlled for consistent, reliable performance
|
|
Operating Specifications
|
|
|
|
Supply
Voltage
|
9 to
32VDC
|
|
Supply
Current
|
ISOL
+ 50mA
|
|
Output
Current
|
DRF-x06:
600mA MAX.
DRF-x12: 1.2A
MAX.
DRF-x25:
2.5A MAX
|
|
Solenoid
Resistance
|
2W
MIN.
|
|
Reference
Voltages
|
-10V, +10V
@ 20mA
|
|
Dither
Settings
|
30,
50, 75, 100, 125, 150, 175, 200, 225, 250, 275, 300, 1000 Hz
|
|
Analog
Input Range
|
DRF-Vxx:
-10V
to 10V
DRF-Axx:
0 to 20mA
|
|
Analog
Input Impedance
|
DRF-Vxx:
38kW
DRF-Axx:
250W
|
|
Analog
Input Resolution
|
10 bits |
|
Operating
Temperature Range
|
-20º to 70º
C
|
|
Enclosure
|
Polyamide
|
|
Dimensions
|
Inch:
0.69 W x 4.50 H x 4.30 D
mm:
17.5 W x 114.5 H x 109.4 D
|
|
|
User's Manual
|
|
|
For detailed information about the DRF, download the User's Manual: D-DRF-A.PDF
|
|
|
Part Numbers
|
|
|
|
The
following part numbers are available in the DRC series:
| DRF |
ch
|
-in
|
out
|
|
| |
2
|
-
|
-
|
2 Input/Output Channels |
| |
4
|
-
|
-
|
4 Input/Output Channels |
| |
|
V
|
-
|
Voltage Input -10V to +10V |
| |
|
A
|
-
|
Current Input 0 to 20mA |
| |
|
C
|
-
|
CANopen* |
| |
|
D
|
-
|
DeviceNet* |
| |
|
J
|
-
|
J1939* |
| |
|
|
06
|
600mA Output |
| |
|
|
12
|
1.2A Output |
| |
|
|
25
|
2.5A Output |
Example: DRF4-V06 - 4 output channel, voltage input, 600mA outputs
*Future Product. Please contact us for more information.
|
|
|
Ordering Information
|
|
|
|
List Price:
DRF2-xxx - $415.00
DRF4-xxx - $575.00
To
order products,
Email:
orders@whiteoakcontrols.com
Fax:
877-469-9815 Buy Online
|

Copyright