ProValve 100

 

CompanyProductsNewsContact Us
MVPProValveAccessories
ProValve 100ProValve 200
 

ProValve 100

 

Description

 

The ProValve 100 is an electronic control module for use with proportional solenoid valves in open loop systems.  The module will provide current to the solenoids of the valve in response to various types of signals provided by the control system.  Indicators on the front of the module provide an overview of the operating status.  System configuration is accomplished through a convenient remote terminal.  All settings are stored in permanent memory within the unit.  The unit is housed in an attractive, compact enclosure.

Features

 

  • Various control input options including analog, digital and mixed
  • Easily configured using WhiteOak Windows based software, a hand-held interface, or terminal emulation software
  • Front panel indicators for Power, Output Current and System Faults
  • Standard 35mm DIN rail mounting
  • Removable terminals to simplify wiring and maintenance
  • Efficient 15.6 kHz PWM operation
  • Selectable dither frequency up to 244 Hz
  • Adjustable current limited output with short circuit protection
  • Reference voltage outputs for potentiometer/joystick controls
  • Independently adjustable gain and deadband for input and output
  • Four independent ramp times for flexible discrete input control
  • Microprocessor controlled for consistent, reliable performance

Operating Specifications

 

Supply Voltage

12 to 30VDC

Supply Current

ISOL + 50mA†

Output Current

Standard:  2.5A MAX.  

-L:  500mA MAX.

Solenoid Resistance

Standard:  2W MIN.

-L:  10W MIN.

Reference Voltages

-10V, +10V @ 2mA

Dither Settings

Off, 35, 41, 49, 61, 81, 122, 244 Hz

Ramp Time

0.10 to 16.96 seconds

Analog Input Range

0 to 10V, -10V to +10V, 0 to 5V, -5V to +5V, 0-20mA, 4-20mA

Analog Input Impedance

INVR > 100kW, INIR = 500 Ohms

Digital Input Range

-24  12 to 30 VDC Positive or Negative Logic

-115  100 to 130 VAC

-230  210 to 250 VAC

Digital Input Impedance

-24    3.3kW

-115  33kW

-230  75kW

Operating Temperature Range

0º to 70º C

† Additional current is required when the hand held interface is attached.

 

User's Manual

 

For detailed information about the ProValve 100, download the User's Manual: 
D-PV100-G.PDF

 

Part Numbers

 

 

The following part numbers are available in the ProValve 100 series:

  • PV100-24 - 12 to 30 VDC digital input range
  • PV100-115 - 100 to 130 VAC digital input range
  • PV100-230 - 210 to 250 VAC digital input range

 

Ordering Information

 

 

To order products,

Email:  orders@whiteoakcontrols.com

Fax:  877-469-9815

[Up][Next]

Copyright © 2005 WhiteOak Controls, Inc. All rights reserved.

info@whiteoakcontrols.com